OMPT GROUPE worked in Vallauris to create a new window in a load-bearing facade wall. The client wanted to bring more natural light into their home. As the wall is load-bearing, the opening required a combined steel and reinforced concrete reinforcement, carried out according to the engineering office’s plan.
Why a load-bearing facade must be reinforced before opening it
A load-bearing facade wall carries the loads of the floors and often part of the roof. Cutting a window into this wall removes an area that transferred these forces down to the foundations. Without reinforcement, the masonry above the opening may crack or sag.
So, before the opening is freed, a structure must be created that can take up these loads and carry them down on each side.
Propping and securing the facade
Before any cutting, we installed temporary props to support the floor and the masonry throughout the works. This step keeps the structure stable while the window is being created.
Building the reinforced concrete columns
On each side of the future opening, we built two reinforced concrete columns. They frame the window and serve as supports for the new structure. They carry the loads continuously down into the existing wall, without stressing the masonry weakened by the cut.
Installing the two HEA 160 beams
Above the opening, the lintel is made of two HEA 160 steel beams resting on the reinforced concrete columns. This combined reinforcement brings together:
- the strength of the steel sections, which span the opening while limiting deflection;
- the robustness of the reinforced concrete supports, which spread the loads into the wall.
Once the structure was in place and loaded, the opening was cut and the props removed.
A new window in the facade in Vallauris
The facade now has a new window, and the home enjoys more light. The structure remains safe thanks to a steel and reinforced concrete reinforcement adapted to the load-bearing wall.
OMPT GROUPE creates windows and openings in load-bearing walls, installs steel beams (IPN, HEA, UPN) and carries out reinforced concrete reinforcement in Vallauris, Golfe-Juan, Antibes, Cannes, Mougins and throughout the Alpes-Maritimes. Do you have a project? Request your quote.