As part of an interior remodelling project in Valbonne, OMPT GROUPE demolished a concrete load-bearing wall and installed a steel reinforcement structure, in line with the technical requirements set by a structural engineering office.
Study and planning
Before any work began, a detailed structural study was carried out by a structural engineer to determine the technical constraints involved in removing the load-bearing wall and the appropriate reinforcement solutions to guarantee the stability of the building.
Work carried out
The chosen method was to install a surface-mounted steel reinforcement structure on each side of the planned opening.
The structure is made of UPN240 sections, firmly anchored to the existing load-bearing wall with threaded rods passing through it in a twin-beam clamping (moisage) arrangement, ensuring an even distribution of loads and lasting stability.
Once all the steel elements were assembled, the structure was coated with an anti-rust paint, ensuring its durability and corrosion resistance.
Result
The work created a large opening in a load-bearing wall while preserving the structural integrity of the building. This load-bearing wall opening with steel reinforcement now offers more light, better circulation and a significant gain in space, while complying with current standards.